Rated design, not catalogue selection
An exchanger picked from a supplier's software is sized to the supplier's assumptions about fouling, allowable pressure drop and margin. When the unit underperforms, the assumptions are what you argue about. We produce an independent rated design first, then use it as the technical basis for the enquiry.
Scope
- Shell-and-tube exchangers to TEMA, with type selection justified
- Thermosiphon and kettle reboilers, including circulation checks
- Overhead and vent condensers, with non-condensable handling
- Falling film and forced circulation evaporators
- Plate and spiral units where fouling or approach temperature demands them
- Air-cooled exchangers and site ambient design conditions
- Vibration, pressure drop and fouling margin checks
Where designs usually go wrong
Three recurring causes: a fouling factor copied from a textbook rather than derived from the service, a two-phase pressure drop that was never checked against the available driving head, and a temperature approach that looked economical on paper and left no margin for a summer ambient. All three are cheap to catch at design stage and expensive to discover at commissioning.
Deliverable
A rated datasheet, the thermal design output file, and a specification suitable for issuing to fabricators for competitive quotation.
Other services
03 · Pilot
Modular pilot plant design
Skid-mounted pilot units for technology validation — P&IDs, equipment specifications, vendor packages and support through commissioning.
DeliverablePilot design package + vendor scope
04 · Basic engineering
Basic engineering package
PFDs, P&IDs, line list, equipment datasheets, utility summary, plot plan and HAZOP participation. The package your EPC prices against.
DeliverableFull BEP
02 · Simulation
Process simulation & scale-up
A validated model regressed against your own lab data, with sensitivity runs on the variables that actually move the design.
DeliverableSimulation file + PFD with stream table
05 · Equipment
Heat exchanger thermal design
Rated design of exchangers, reboilers and condensers. Column, dryer, evaporator and membrane sizing where separation drives the economics.
DeliverableRated datasheets + TEMA specification
01 · Feasibility
FOAK process engineering
First-of-a-kind processes have no reference plant. We build the design basis from your chemistry and name the three risks that decide the project.
DeliverableDesign Basis Memorandum + BFD
06 · Detailed design
Detailed engineering to IFC
Mechanical, piping, electrical and instrumentation taken to issued-for-construction with vetted partners under our technical coordination.
DeliverableIFC drawing set + specifications